Vlamboog detectie systemen
Vlamboog detectie systemen
Vlamboog bescherming voor snelle detectie van vlambogen op conductors, schakelapparatuur en bijbehorende kabeldozen.
1S20 Arc Flash Monitor – 3 point sensors / 2 zones
- Simple panel mounting for retrofit applications
- One, two or three independent arc sensor inputs
- Two high speed tripping output contacts
- Push button reset
- Integrated self-supervision with fail alarm contact
Bekijk details
1S23 Arc Flash Module – 2 point sensors / 1 zone
- Simple panel mounting for retrofit applications
- One, two or three independent arc sensor inputs
- Two high speed tripping output contacts
- Push button reset
- Integrated self-supervision with fail alarm contact
Bekijk details
1S24 Arc Flash Monitor – 16 point or 12 point + …
- Up to 16 arc fault sensors
- Up to 16 independent arc fault SARC logic nodes
- Arc fault signaling via Ethernet IEC61850 GOOSE messaging
- 10Base-T / 100Base-TX port
- Optional 100Base-FX port
- Trip indication LED for each arc fault sensor
- Continuous arc sensor supervision with sensor fail LED for each zone
- Non volatile memory ensures last recorded alarm states are restored on power up
Bekijk details
1S25 Arc Flash Monitor – 8 point sensors / 4 zones
- Up to 16 arc fault sensors
- Up to 16 independent arc fault SARC logic nodes
- Arc fault signaling via Ethernet IEC61850 GOOSE messaging
- 10Base-T / 100Base-TX port
- Optional 100Base-FX port
- Trip indication LED for each arc fault sensor
- Continuous arc sensor supervision with sensor fail LED for each zone
- Non volatile memory ensures last recorded alarm states are restored on power up
Bekijk details
1S26 Arc Flash Monitor – 8 point sensors / 4 zon…
- Up to 16 arc fault sensors
- Up to 16 independent arc fault SARC logic nodes
- Arc fault signaling via Ethernet IEC61850 GOOSE messaging
- 10Base-T / 100Base-TX port
- Optional 100Base-FX port
- Trip indication LED for each arc fault sensor
- Continuous arc sensor supervision with sensor fail LED for each zone
- Non volatile memory ensures last recorded alarm states are restored on power up
Bekijk details
1S30 Optical Arc Fault Point Sensor
- Up to 16 arc fault sensors
- Up to 16 independent arc fault SARC logic nodes
- Arc fault signaling via Ethernet IEC61850 GOOSE messaging
- 10Base-T / 100Base-TX port
- Optional 100Base-FX port
- Trip indication LED for each arc fault sensor
- Continuous arc sensor supervision with sensor fail LED for each zone
- Non volatile memory ensures last recorded alarm states are restored on power up
Bekijk details
1S40 Optical Arc Fault Linear Sensor
- Linear sensor for wide of arc protection coverage
- Optional sensor fibre length
- Optional link fibre length
- Loop topology allows sensor supervision
- Robust and durable 2mm plastic optical fibre
- Suits RMS 1S24 and 1S27 arc fault monitors
- Sensor length up to 35 meters
- Sensor link adds another 40 meters in length
- Robust and durable 2mm plastic optical fibre
- No special tools required for installation
- Supplied with 2x fibre couplers
- Supplied with fibre cutter
Bekijk details
Delta 1S27 Arc Flash Monitor – 4 point + 1 linea…
- Less than 7ms arc detection and tripping time
- Four (4) point sensor inputs
- Optional linear sensor input
- Surface or rail mount
- Flush panel or rack mount
- Made in Australia
Bekijk details